cam-bien-do-luc-cang-fs1-50k-422-fs1-2000-422-fs1-1000-422-fs1-50-422.png
Tension Sensor FS1-422
  • 10 Tension ranges available:
    from 0 - 50 cN
    up to 0 - 50 daN
  • Application:
    Wire and textile industry
  • Field of use:
    Threads up to 50.000 tex and wires up to approx. Ø 2 mm
  • Feature:
    - With RS 422 interface for multi station system
    - Versatile tension sensor
10 Tension ranges available from 0 - 50 cN up to 0 - 50.00 daN

Stationary electronic tension sensor for measuring threads, fibres and thin wires with a diameter up to approx. 2 mm

Universal sensors for continuous tension measuring in wire and textile industry

Tension sensor with RS 422 output for multi station system and connection to a with PC

Special Features

Tension sensor FS1-422 with integrated microprocessor controlled measuring amplifier and RS 422 interface for multi station system
 
Different guide rollers are available, according to the application
 
Easy installation, even afterwards, on existing machines
 
2 Mounting possibilities: housing mounting or cylindrical hole mounting (mounting cut out: longhole R 19 mm, length 54 mm)
 
Easy calibration to customized material by operator – zero and gain calibration is required
 
Measuring principle – loadcell with high quality strain gauge bridge
Tension sensor with mechanical overload protection

 Standard Features

 
V-grooved guide rollers, ball-bearing mounted
 
Control lamp shows operative mode availability
 
Tension sensor FS1-422 with aluminium housing
 
CAT 5 cables are used for data transfer
 
Required power supply +15…24 V DC (regulated)
 
Certificate of Compliance with the order 2.1 according EN 10204 is included
 
Optionally available: Inspection Certificate 3.1 according EN 10204 with calibration report

 

Special features of the RS 422 interface:

  • Up to 32 sensors with different tension ranges and designs may be connected in one line (data transfer max. 200 readings/sec.)
  • Connection to RS 232 using a converter (RS 422 – RS 232).
  • The RS 422 signal can be used for a single sensor over a distance of 1000 m.
  • Each sensor can individually be addressed and set up
  • Can be connected to PLC controls with digital input
  • Simple connection to BUS-Systems using gateways

Available Models

Model Measuring Range Measuring Head Width* SCHMIDT Calibration Material**
FS1-50-422 0 – 50 cN 64 mm PA: 0.12 mm Ø
FS1-100-422 0 – 100 cN 64 mm PA: 0.12 mm Ø
FS1-200-422 0 – 200 cN 64 mm PA: 0.12 mm Ø
FS1-500-422 0 – 500 cN 64 mm PA: 0.20 mm Ø
FS1-1000-422 0 – 1000 cN 64 mm PA: 0.30 mm Ø
FS1-2000-422 0 – 2000 cN 124 mm PA: 0.50 mm Ø
FS1-5000-422 0 – 5000 cN 124 mm PA: 0.80 mm Ø
FS1-10K-422 0 – 10 daN 124 mm PA: 1.00 mm Ø
FS1-20K-422 0 – 20 daN 224 mm PA: 1.50 mm Ø
FS1-50K-422 0 – 50 daN 224 mm steel rope 1.50 mm Ø
Other tension ranges and measuring head widths available on request.
Other measuring units available, such as g or kg.
* Outer dimensions of front plate
** Suitable for 95 % of applications PA = Polyamide Monofilament